Interlocking polycarbonate panels are sold as a system, not as a sheet. The panel is only one of three parts: the panel spans between openings, an H-profile joins panel to panel with no visible fastener, and U-profiles close the top and bottom edges and carry the water out. Buy the panel alone and it will not go together on site, which is the single most common problem with this product.
Request a Quote Ask for Free Samples

This page is the buying page for the interlocking range: what the system consists of, how to estimate the profiles before you order, what a complete quotation has to contain, and where this system is the wrong choice. Panel dimensions and performance data are in the 2026 specification sheet, the application-by-application choice in the selection guide, and the joint mechanics in H-profile joints.
Interlocking Polycarbonate Panel Specifications
Panel range
| Thickness | 6 / 8 / 10 mm |
|---|---|
| Panel width | 500 / 600 / 900 / 1000 mm |
| Panel length | Cut to order, up to 6000 mm |
| Structure | Twin-wall and triple-wall, clear and tinted |
| Light transmission | Clear up to 88 %; opal 40–55 % |
| UV protection | Co-extruded both faces |
| H-profile | Aluminium or polycarbonate, 10–20 mm face |
| U-profile | Aluminium, with weep holes at 300 mm centres |
| Thermal movement | Allow 3 mm per 1.2 m of panel length |
| Service temperature | −40 °C to +120 °C |
| Reaction to fire | B-s1,d0 to EN 13501-1 |
| Minimum order (MOQ) | 1 × 20GP container — mixed sizes and colours accepted |
Three Components, One System
| Component | What it does | If it is missing |
|---|---|---|
| Panel | Spans the opening and carries the weather | Nothing to install |
| H-profile | Joins two panels, hides the fastener, allows movement | Panels cannot be joined; visible screws and leaks |
| U-profile | Closes the top and bottom edge, drains the cavity | Open ends take water and dust; the panel stains from inside |
| Corner profile | Closes an external corner between two faces | Corners stay open or get sealed badly on site |
| Sealing tape | Filters the top edge, breathes at the bottom | Insects and dust in the chambers, condensation inside |
This is why a quote for panels per square metre is not comparable with a quote for the system per square metre. The second one includes the profiles; the first one leaves the buyer to source them locally, and locally sourced profiles usually do not match the panel thickness.
Estimating Profiles Before You Order
Two calculations decide the order, and both are worth doing before the quotation rather than after the delivery:
Panel count. Number of panels = opening width divided by panel width plus profile face, rounded up. Then check the actual covered width: panels × panel width + (panels − 1) × profile face. If the result is wider than the opening, the last panel gets cut — so order that panel oversize.
Profile length. H-profile runs the full height between every pair of panels, so its length is (panels − 1) × panel height. U-profile runs along the top and bottom, so its length is 2 × opening width per face. Corner profiles run the full height at each external corner.
A worked example: an opening 5000 mm wide and 3000 mm high, 900 mm panels with a 20 mm profile face. Panels = 5002 ÷ 920 = 5.4, so 6 panels. Covered width = 6 × 900 + 5 × 20 = 5500 mm, so the last panel is cut to 400 mm. H-profile = 5 runs × 3000 mm = 15 m. U-profile = 2 × 5000 mm = 10 m. That is the order, and it is the number most buyers get wrong the first time.

What a Complete Quotation Has to Contain
- Panel thickness, colour and quantity, with the cut panel called out separately.
- H-profile, U-profile and corner profile in metres, matched to the panel thickness.
- Sealing tape: dust tape for the top edge, breather tape for the bottom.
- Fixing components — base brackets, screws and washers — if the system includes them.
- Packing: how the panels and the profiles are bundled, and whether the profiles ship inside the panel stack or separately.
If a supplier quotes only the panels, ask for the profile schedule as well. It is a two-minute question and it separates a system supply from a sheet sale.
Panel Thickness and Cover Width
- 6 mm — screens, partitions, light boxes. Light and inexpensive, but it flexes on a wide face.
- 8 mm — the general-purpose facade and partition thickness, and the most common specification.
- 10 mm — larger spans, higher wind load, and interiors where stiffness matters.
- Width. 900 mm panels are the usual balance of handling and appearance; 500 mm and 600 mm panels give a finer rhythm on smaller elevations; 1000 mm panels reduce the profile count on long runs.
Where Interlocking Wins and Where It Does Not
| Situation | Interlocking system | Alternative |
|---|---|---|
| Facade or partition with no visible fasteners | The reason the system exists | Screwed panel: fasteners on show |
| Roofing | Limited — and never butted end to end | Multiwall roofing with laps |
| Fast assembly and dismantling | Good, dry-glazed and reversible | Screwed or bonded panels |
| Interior screens and exhibition work | Good: light, clean joints, coloured options | Glass: heavier and fragile |
| Lowest cost per m² | Not this system, once profiles are counted | Corrugated or screwed panel |
Supply, Packing and Container
- Length. Cut to order up to 6000 mm; a 20 ft container takes around 5800 mm, so a 6000 mm panel needs a 40 ft or a splice.
- Packing. Panels filmed and banded; profiles bundled separately and labelled with the panel thickness they match.
- One batch per elevation. Tinted panels vary slightly between production runs, and a facade is one continuous surface.
- Spares. Hold 2 to 5% of panels and a few metres of each profile — replacing a damaged panel across an interlocking face is easier than it looks, provided the profile and the batch match.
Where We Are Honest About the Limits
- The profiles are not commodity parts. An H-profile from a different supplier usually does not match the panel thickness or the rib spacing. Mixing them is how facades end up with gaps.
- It is not a structural system. The panel spans between supports; the wind load has to be carried by the framing behind it, and we will ask for the wind load and the support spacing.
- End-to-end joints are not allowed on a slope. Two panels cannot be butted in the same run without a proper junction profile, and water will find the mistake.
- Thermal movement is real. At roughly 0.065 mm per metre per degree, a 3 m panel moves about 2 mm over a 10 °C swing, and the joint has to allow it rather than clamp it.
- Not the cheapest option. Once profiles and accessories are counted, an interlocking face costs more than a screwed panel. It is bought for how it looks and how it goes together, not for the lowest number.
More on Interlocking Polycarbonate
Panel sizes, colours and performance data are in the specification sheet; which thickness suits which application in the selection guide; and how the joints behave under movement in H-profile joints. Everything published on this range is indexed in the interlocking panel articles.
Interlocking Polycarbonate Panels: Common Questions
Yes. An interlocking panel is one part of a system: H-profiles join panel to panel, U-profiles close and drain the top and bottom edges, corner profiles close external corners, and sealing tape keeps dust and insects out of the chambers. Panels alone cannot be installed.
One run of H-profile between every pair of panels, running the full panel height. For six panels that is five runs, so the length is five times the panel height. U-profile is two runs of the opening width per face, top and bottom.
8 mm, for facades and partitions. Use 6 mm for screens and light boxes where the span is short, and 10 mm where the span is larger, the wind load is higher, or the surface has to be stiffer.
Only with care, and never butted end to end within a slope. The system is designed as a vertical facade and partition product; roofing is better served by multiwall sheet with proper laps. Ask us before specifying it overhead.
Because a panel-only price is not comparable with a complete system price, and locally sourced profiles frequently do not match the panel thickness or rib spacing. A mismatched profile shows up as gaps and leaks on the finished face.
About 0.065 mm per metre per degree, so roughly 2 mm for a 3 m panel over a 10 degree swing. The joint must allow that movement, which is why the panel is fixed and the profile is not.
Send your opening sizes and we will price the panels and the profiles together
Send us these four details and we will come back with a landed cost:
- Sheet type and thickness
- Size and quantity
- Application (roof / skylight / partition...)
- Destination country or port
Related Articles
- Interlocking Polycarbonate Panel Selection Guide 2026: How to Choose the Right Thickness and Structure
- Interlocking Polycarbonate Panel Specifications 2026: Complete Thickness, Width and Structure Guide
- Interlocking Polycarbonate Panels for Modern Office Partitions — Durable, Lightweight & Cost-Effective