The short answer
A tender that names only “polycarbonate sheeting” invites three suppliers to quote three different products, and the bid with the lowest number usually wins on omissions rather than value. When you specify polycarbonate sheeting properly, you fix the material grade, structure, thickness, UV layer, dimensions, fire rating and warranty so every bidder prices the same product and the contract cannot be quietly downgraded after award. This guide lists the twelve fields a specification should contain, the gaps suppliers most often exploit, and how the same document should read differently for a solid sheet roof than for a multiwall greenhouse.
Why a vague specification is the most expensive line in a tender
Polycarbonate is a family, not a single product. A solid sheet, a twin-wall panel and a corrugated profile are all polycarbonate sheeting, yet they differ in structure, thickness range, thermal performance, load capacity and price. When the document does not separate them, one bidder can quote a 4 mm twin-wall panel against another bidder’s 10 mm multiwall panel and both have technically complied with the wording. The buyer only finds the difference after installation, when the roof deflects under snow load or the light transmission is half what the design assumed.
Every field you leave open is a decision you have handed to the lowest bidder, and the lowest bidder does not choose the option that protects your project. They choose the option that lets them win the tender. A specification is not paperwork; it is the mechanism that keeps the product you were promised the same as the product you are delivered.
How to specify polycarbonate sheeting: the twelve fields
A complete specification has twelve fields. Below is the checklist with an example of what each line should state. Where a field is left blank, state in the tender that it must be answered in the submission — silence is how a bidder’s assumption quietly becomes your liability.

| Specification field | What the tender should state |
|---|---|
| Material grade | Virgin polycarbonate, UV-stabilised, no recycled content |
| Sheet structure | Solid, twin-wall, multiwall or corrugated profile |
| Thickness | e.g. 6 mm, 8 mm, 10 mm or 16 mm |
| Sheet size | e.g. 2100 x 5800 mm, cut to size or standard |
| UV protection | Co-extruded layer, 50 µm, one or both sides |
| Light transmission | Clear ~80%, opal 35-60%, by colour |
| Colour | Clear, opal, bronze, blue or green |
| Fire rating | EN 13501 class, e.g. B-s1,d0 or equivalent |
| Wind and snow load | Design load in kN/m2 or kg/m2 |
| Thermal insulation | U-value in W/m2K, stated by thickness |
| Expansion allowance | About 0.065 mm per metre per degree C |
| Warranty | e.g. 10-year yellowing and light transmission warranty |
Thickness is the field that drives the rest, so it belongs in the document as a fixed value rather than a range wherever the span and load are already known. Our solid polycarbonate sheet selection guide walks through how thickness, UV coating and impact resistance map to a specific application.
Where suppliers quietly cut corners
The fields suppliers hope you leave open are not the obvious ones. They are the ones that cost money to honour: the thickness of the UV layer, the tolerance on cut length, the fire certificate that matches your local building code, and the warranty terms that say who pays for replacement. A specification that says “UV protected” without a thickness or a side allows a co-extruded layer too thin to survive a decade outdoors, and it is still a compliant bid.
Light transmission is another favourite gap. Two panels can both be called “opal” while one passes 60% of light and the other 35%. If the building relies on daylight, write the transmission figure you need and let the bidder confirm it. Our light transmission and diffusion guide explains how the figures are measured and what they mean in a real roof.

Specifying by application: multiwall or solid
The same twelve fields read differently depending on the product. For a thermally insulated roof or a greenhouse you will usually specify a multiwall panel and pin down its thickness and U-value; for a clear, impact-resistant face, a machine guard or a flat glazing panel you specify a solid sheet and pin down its thickness and impact class. Writing “polycarbonate sheeting” instead of choosing one lets the bidder substitute a cheaper structure on the same thickness, which changes everything downstream.
Both product families and their full thickness and configuration ranges are covered on our multiwall polycarbonate sheets and solid polycarbonate sheets pages, so the specification can reference a real, nameable product rather than a generic phrase.

Customisation and supply scope
State clearly what is fixed and what is open. Standard sheet sizes, cut-to-size, colour matching and UV side marking should be written down; so should the lead time and the packaging. If the project needs sheets longer than the standard 5800 mm, or a colour that has to be matched across batches, say so in the document — these are the clauses that prevent a post-award renegotiation. A sheet is supplied with a protective film on the UV side, and the specification should state that the film stays on until installation and is removed at the right moment, so the panel is not fitted facing the wrong way.
Warranty and compliance: write it, do not assume it
A warranty that is not written into the tender does not exist. State the years of coverage, what it covers — yellowing, loss of light transmission, delamination — and what the supplier’s obligation is when a panel fails. Ask for the test reports and certificates in the submission itself, because a bidder who cannot attach the fire certificate at tender stage usually cannot produce it later either. We are a manufacturer of polycarbonate sheets, so the specification, the test data and the warranty come from the same source, which is what a compliance clause is really trying to guarantee.
Frequently Asked Questions
What is the minimum information a tender should contain for polycarbonate sheeting?
At minimum, material grade, sheet structure, thickness, sheet size and UV protection. Those five fields are enough to stop a bidder quoting a different product; the remaining seven fields (light transmission, colour, fire rating, load, U-value, expansion allowance and warranty) prevent disputes after award.
Should I specify virgin or recycled polycarbonate?
Specify virgin, UV-stabilised polycarbonate for anything exposed to weather. Recycled content lowers impact strength and accelerates yellowing, and it is exactly the downgrade a vague specification invites. If a bidder proposes recycled material, make them state the percentage and its effect on the warranty in writing.
What does a co-extruded UV layer mean and why does its thickness matter?
It means the UV absorber is fused into the outer surface of the sheet during extrusion, not sprayed on afterwards. The thickness of that layer — commonly 50 µm for outdoor use — is what determines how many years the sheet resists yellowing. A specification that says “UV protected” without a layer thickness lets a bidder supply a far thinner layer.
How do I set the right thickness for my span and load?
Thickness follows span, support spacing and the design snow and wind load, not preference. Give the supplier the span and the load and ask for the thickness they will confirm in writing; if two bidders return different thicknesses for the same span, one of them is not accounting for the load.
What warranty terms should I write into the tender?
Ten years against yellowing and against loss of light transmission beyond a stated limit is a reasonable benchmark, plus a clause on who pays for replacement labour. Ask for the warranty wording in the bid, not after award, and check it names the product and the UV side.
Need a specification you can put straight into the tender?
Send us four things and we will return a matched specification with a quote for your project — the structure, thickness, UV configuration and size that fit your span and load.
- Application — greenhouse, factory roof, canopy, walkway or other use
- Sheet size and thickness — e.g. 8 mm, 2.1 m x 5.8 m
- Quantity — number of sheets or total square metres
- Destination country or port