Multiwall Polycarbonate Sheets

Multiwall polycarbonate sheet is the hollow-chamber sheet for roofing and glazing: parallel walls joined by internal ribs, so it carries load and insulates at a fraction of the weight of solid sheet or glass. We extrude it from 4 mm to 30 mm, twin-wall to honeycomb, UV-protected on both faces.

Request a Quote Ask for Free Samples

Multiwall polycarbonate sheet cross section showing twin-wall and triple-wall hollow chambers

This page is the buying page for the multiwall range: which structure and thickness to specify, how it compares with solid, corrugated and glass, and what we need to quote it. The detailed thickness-by-thickness breakdown lives in our multiwall thickness guide, and the full test data in the 2026 specification sheet — both are worth reading before a large order, and this page is what you send to a colleague who needs the summary.

Multiwall Polycarbonate Sheet Specifications

Range at a glance

Thickness4 / 6 / 8 / 10 / 12 / 16 / 20 / 25 / 30 mm
StructuresTwin-wall, triple-wall, five-wall, X-structure, honeycomb
Standard width1220 mm and 2100 mm
LengthCut to order; 5800 mm and 11800 mm suit 20 ft and 40 ft containers
ColoursClear, bronze, opal, blue, green, silver, grey
Light transmissionClear 82–90 % depending on thickness; opal 40–50 %
UV protectionCo-extruded both faces, 50–80 μm
U-value3.8 W/m²K at 4 mm down to 1.2 W/m²K at 35 mm
Weight0.8 kg/m² at 4 mm to 3.5 kg/m² at 25 mm
Service temperature−40 °C to +120 °C
Reaction to fireB-s1,d0 to EN 13501-1
StandardEN 16153 for multiwall polycarbonate sheets
Minimum order (MOQ)1 × 20GP container — mixed sizes, colours and thicknesses accepted

Choosing the Structure

The wall count is not a quality grade — it is a way of buying insulation and stiffness without adding weight. Each step up costs more and transmits slightly less light.

StructureUsual thicknessChoose it when
Twin-wall4 – 10 mmGeneral glazing, carports, canopies, partitions. The default and the most economical per m².
Triple-wall10 – 16 mmThe space below is heated, or condensation is a known problem.
Five-wall16 – 25 mmInsulation is the driver and the budget allows it — greenhouses with climate control, roof lights over heated rooms.
X-structure6 – 10 mmLoad or point impact matters more than insulation: walk-on protection, high snow load, machinery areas.
Honeycomb8 – 16 mmStrength plus sound reduction together — screens, enclosures, barrier panels.

Two structures at the same thickness are not interchangeable. An X-structure sheet at 8 mm is stiffer than a twin-wall at 8 mm but insulates less; a five-wall at 16 mm insulates far better than a triple-wall at 16 mm, at a higher cost and slightly lower light transmission.

U-Value Decides the Thickness, Not Habit

Most projects get their thickness from whatever the last job used. The correct starting point is the U-value the space actually needs, read backwards:

U-value neededThickness and structureTypical application
Around 3.5 – 3.84 – 6 mm twin-wallUnheated: carports, open canopies, screens, cold frames
Around 3.38 mm twin-wallGreenhouses, livestock sheds, covered walkways
Around 2.910 mm twin or tripleSemi-heated space, retail canopies, entrance roofs
Around 2.316 mm triple or five-wallRoof lights over heated rooms, pools, atria
1.4 – 1.225 – 35 mm multi-wallWhere the glazing is part of the thermal envelope

For a heated building, glass or solid sheet is a poor comparison: single glazing sits near 5.8 W/m²K and solid polycarbonate is the same. The multiwall structure is the whole point — at 25 mm it performs close to a double-glazed unit at a fraction of the weight.

One caveat before thickness is used as a cure-all: in a humid space, more thickness alone does not stop condensation. If the roof drips, the answer is an anti-drip surface plus ventilation, not simply a thicker sheet — the mechanism and the numbers are in why polycarbonate roofs drip.

Factory roof daylighting strips glazed with multiwall polycarbonate between metal roof sheets

Multiwall vs Solid vs Corrugated vs Glass

PropertyMultiwallSolid PCGlass
Insulation (U-value)3.8 down to 1.25.85.8 single, 2.8 double
WeightLightestHeavyHeaviest
ImpactHigh; dents, does not shatterHighestBreaks
Large spansGood with the right structureNeeds closer supportsNeeds laminated build-up
Visual clarityGood, visible ribsBestBest
Where it winsRoofs where insulation mattersGuards and screensPrestige façades

The choice usually settles quickly once the question is framed properly: if the sheet is part of the thermal envelope, use multiwall; if the job is impact or vandal resistance, use solid; if it has to line up with a trapezoidal metal roof, use corrugated single-skin sheet, which matches the profile but insulates far less; if the client is paying for optical perfection and accepts the weight and breakage risk, use glass.

Width, Length and How It Ships

Sheet length is a commercial decision, not just a technical one, because container length caps it:

  • Width. 1220 mm and 2100 mm are standard. 2100 mm halves the number of runs and the number of rafters, which usually saves more on the frame than the wider sheet costs.
  • Length. Cut to order. A 20 ft container takes about 5800 mm and a 40 ft about 11800 mm, so a panel 200 mm over the limit does not ship — it gets spliced on site instead, which is worse.
  • Weight in the container. Multiwall is light, so most shipments cube out before they weigh out. That makes packing quality and crate size the limiting factor, not tonnage.
  • Accessories. Closure profiles, H-connectors, anti-dust tape, breather tape and fixing buttons ship with the sheet. Specify them with the order; sourcing them locally is where most site delays start.

Fabrication and Fixing

  • Cut with a fine-tooth blade or a sharp knife; leave the protective film on while cutting.
  • Seal the top edge with anti-dust tape and the bottom edge with breather tape — sealing both ends traps moisture inside the chambers.
  • Drill holes 2 to 3 mm larger than the fastener, and never over-tighten: the sheet must be able to move.
  • Allow for thermal movement at roughly 0.065 mm per metre per degree; long runs need a connector, not a butt joint.
  • Never walk on the sheet unless it is specified and supported for it — use crawling boards across the purlins.

Where We Are Honest About the Limits

  • The ribs are visible. Look up through multiwall and you see the chamber pattern. Where the client expects an optically clean surface, solid sheet or glass is the right product and we will say so.
  • It is not a wall. Even at 35 mm the U-value is about 1.2 W/m²K, which is far better than single glazing and far worse than an insulated wall. It is glazing, and should be compared with glazing.
  • Snow load is a structural question. The sheet has span limits that depend on thickness, structure, purlin spacing and snow zone. We calculate it — but we need the span and the load, not just the sheet size.
  • Anti-drip is a surface treatment, not a cure. It stops droplets forming and falling; it does not remove the moisture. Ventilation still has to be designed.
  • Chemical exposure is a real constraint. Solvents, alkalis and some agricultural disinfectants stress-crack polycarbonate. Where the roof sits above a chemical or intensive livestock environment, the exposure has to be checked before the order, not after.

More on Multiwall Polycarbonate

Thickness by thickness, fixing details, condensation, and which grade suits carports and greenhouses are covered in our multiwall polycarbonate guides and articles. For a carport or greenhouse specifically, thickness and UV layer for carports and greenhouses answers the question most buyers actually arrive with.

Multiwall Polycarbonate Sheet: Common Questions

For an unheated greenhouse 8 mm twin-wall is the usual starting point; 10 mm or triple-wall where the house is heated or humidity is high. Thickness should follow the U-value the space needs rather than the size of the structure.

It depends on thickness, structure and purlin spacing, and it is a calculation rather than a rule. As a rough guide 8 mm twin-wall over 600 to 800 mm purlins and 16 mm over 1000 mm or more, but the snow load at the site decides. Send the span and load and we will confirm.

No. It insulates better than single glazing, which reduces condensation, but humid air still condenses on a cold surface. An anti-drip surface stops droplets forming and falling, and ventilation removes the moisture. Both are needed.

Twin-wall has two walls and one row of chambers, triple-wall has three walls and two rows. Triple-wall insulates better and is used for heated spaces and condensation-prone roofs; twin-wall is the economical default for carports, canopies and general glazing.

Yes, and it is one of the few glazing materials that makes sense there without the weight of glass. At 16 mm the U-value is around 2.3 W/m2K and at 25 mm about 1.4, which is close to a double-glazed unit at a fraction of the weight.

Anti-dust tape on the top edge and breather tape on the bottom edge. Sealing both ends with a non-breathable tape traps moisture inside the chambers; leaving both open lets dust and insects in.

Send your span, load and quantity for a quotation

Send us these four details and we will come back with a landed cost:

  1. Sheet type and thickness
  2. Size and quantity
  3. Application (roof / skylight / partition...)
  4. Destination country or port