PVC sheets are the material you choose when the job needs chemical resistance and machinability rather than impact strength. It comes in two forms that are sold under the same name and behave very differently: rigid PVC-U, a dense structural sheet for tank linings, ductwork and clean room walls, and foam PVC, a lightweight expanded board for signage, cabinets and interior fit-out. The temperature limit — about 60 °C in service — is what rules it out of anything exposed to sun.
Request a Quote Ask for Free Samples

This page covers the two material types, thickness selection, where PVC beats polycarbonate and where it fails, fabrication and welding, and what to specify for a quotation. Detailed grades, forming rules and application notes are in the PVC sheet specification guide, and the PVC sheet articles index everything published on this range.
PVC Sheets Specifications
Range at a glance
| Material | Rigid PVC-U and expanded foam PVC |
|---|---|
| Rigid thickness | 1 – 20 mm (to 30 mm on request) |
| Foam thickness | 2 – 10 mm (to 25 mm on request) |
| Density | Rigid 1.40 g/cm³ |
| Sheet size | 1220 × 2440 mm standard; 1000 × 2000 and 1500 × 3000 available |
| Colours | White, grey, black, beige; colour matching on volume |
| Service temperature | 0 – 60 °C continuous |
| Chemical resistance | Good to acids, alkalis and salts; poor to ketones, esters and aromatics |
| Flame | Self-extinguishing, UL94 V-0 on rigid grades |
| Light transmission | Opaque; translucent grades on request |
| Fabrication | Sawing, routing, drilling, hot-air and extrusion welding, thermal forming |
| Standard | EN ISO 1452 for PVC-U sheet and profiles |
| Minimum order (MOQ) | 1 × 20GP container — mixed sizes and colours accepted |
Rigid PVC and Foam PVC Are Different Materials
The two are not interchangeable, and most specification mistakes come from treating them as one product with two prices:
| Property | Rigid PVC-U | Foam PVC |
|---|---|---|
| Density | 1.40 g/cm³ | 0.5 – 0.8 g/cm³ |
| Thickness range | 1 – 20 mm | 2 – 10 mm |
| Strength and stiffness | High; structural | Low; not load bearing |
| Weight for the same thickness | About twice foam | Light |
| Welding | Yes — hot air, extrusion, butt | Difficult; usually bonded or fixed mechanically |
| Machining | Saw, route, drill, tap | Very easy; cuts like wood, takes screws |
| Surface | Gloss or matte, smooth | Matte; embossed and woodgrain available |
| Typical use | Tank linings, fume duct, clean rooms, chemical plant | Signage, cabinets, displays, interior fit-out |
The practical rule: if it has to hold liquid, resist fumes or be welded into a continuous membrane, it is rigid PVC-U. If it has to be cut, routed and screwed together on a bench, it is foam.
Thickness and What Each Range Does
- 1 – 3 mm rigid — chemical tank and duct linings, machine guards, splash protection. Thin enough to form, thick enough to weld.
- 4 – 6 mm rigid — fabricated tanks and troughs, fume hoods, clean room panel cores.
- 8 – 12 mm rigid — self-supporting tank walls, plating lines, structural duct sections.
- 15 – 20 mm rigid — heavy tank walls and machined components where the sheet is also the structure.
- 2 – 5 mm foam — signage, display boards, POS work, model making.
- 6 – 10 mm foam — cabinets, furniture carcasses, exhibition stands, interior wall linings.

Where PVC Beats Polycarbonate, and Where It Fails
Customers often arrive comparing PVC with polycarbonate on price. The honest comparison is about environment, not cost:
| Property | PVC sheet | Polycarbonate sheet |
|---|---|---|
| Chemical resistance | Good to acids, alkalis, salts | Poor — stress cracks |
| Impact strength | Moderate; can crack | Very high; does not shatter |
| Service temperature | 0 – 60 °C | −40 to +120 °C |
| Outdoor weathering | Poor without protection | Good with co-extruded UV |
| Welding | Yes, into a continuous membrane | No practical welding |
| Light transmission | Opaque | Up to 90 % clear |
| Where it belongs | Indoors, chemical plant, tanks, clean rooms | Glazing, roofs, guards, outdoors |
The 60 °C service limit is the one that catches people out. A PVC sheet on a roof in direct summer sun will sag, and a dark PVC sheet in a hot plant room will deform under its own weight. Keep PVC indoors, in chemical service, or as a machined component — and keep polycarbonate for anything that sees sun or impact.
Fabrication, Welding and Bonding
- Sawing and routing. Standard woodworking tooling works; use a sharp blade with a low rake angle and clear the chips, because PVC chips melt and smear if the tool is blunt.
- Welding. Hot-air, extrusion and butt welding all work on rigid PVC-U. A welded joint reaches roughly 60 % of the parent sheet strength, so a tank is designed on the weld, not on the sheet.
- Thermal forming. Heat to 120 – 140 °C for bending and drape forming. Overheating releases hydrogen chloride, so ventilation matters.
- Bonding. Solvent cements work on rigid PVC but not on foam; foam is bonded with contact adhesive or fixed mechanically.
- Machining foam. Cuts like softwood and takes screws and staples directly — which is why it dominates exhibition and furniture work.
- Edge sealing. Cut edges of foam board are porous and need sealing before painting or in damp interiors.
Supply, Colours and Container
- Sizes. 1220 × 2440 mm is the standard sheet; 1000 × 2000 mm and 1500 × 3000 mm are available, and cut-to-size is normal for fabricated work.
- Colours. White, grey, black and beige from stock; colour matching on volume orders.
- Packing. Filmed, interleaved and crated. Foam board is light and bulky, so it cubes out early — plan the container by volume rather than by weight.
- Mixing with polycarbonate. PVC and polycarbonate can ship in one container; heavy rigid sheet goes at the bottom, foam board is stacked separately and never loaded under rigid sheet.
Where We Are Honest About the Limits
- The temperature limit is real. Above 60 °C in service, PVC softens and creeps. Anywhere the sheet is in direct sun or near a heat source, polycarbonate or another material is the correct answer and we will say so.
- It is not an impact material. PVC cracks under a sharp blow where polycarbonate would flex. Guards and barriers should not be PVC.
- Outdoor life needs protection. UV degrades PVC and it chalks and embrittles. Outdoor use requires a cap layer or coating, and even then the life is shorter than polycarbonate.
- Foam board is not structural. It is a fit-out and signage material. Load-bearing or fire-compartment applications need rigid sheet or a different product.
- Weld strength governs fabricated equipment. A welded tank is only as strong as the weld, and we will quote the sheet and the welding rod together rather than pretend the sheet alone is the answer.
- Solvents are the enemy. Ketones, esters and aromatic solvents attack PVC. Where the plant handles those, the lining specification has to be checked against the actual chemical list, not against “PVC is chemical resistant”.
More on PVC Sheets
Grades, forming temperatures, chemical compatibility and application notes are covered in the PVC sheet specification guide, and everything published on this range is indexed in the PVC sheet articles. If you are comparing PVC with polycarbonate for a specific job, send the environment and temperature and we will tell you which one survives it.
PVC Sheet: Common Questions
Rigid PVC-U is a dense structural sheet at 1.40 g/cm3, weldable and used for tank linings, ductwork and clean rooms. Foam PVC is an expanded board at 0.5 to 0.8 g/cm3, light and easy to cut and screw, used for signage, cabinets and fit-out. They are not interchangeable.
About 60 degrees C in continuous service. Above that it softens and creeps, which is why PVC is not used on roofs or near heat sources. Polycarbonate covers minus 40 to plus 120 degrees C.
Only with a UV-protective cap layer or coating, and even then its outdoor life is shorter than polycarbonate. Unprotected PVC chalks and embrittles in sunlight, and in direct sun the surface temperature can exceed its 60 degree service limit.
To most acids, alkalis and salt solutions, yes. To ketones, esters and aromatic solvents, no. Always check the actual chemical list for the plant rather than relying on a general claim.
Rigid PVC-U can be hot-air, extrusion and butt welded, and a welded joint reaches roughly 60 percent of parent sheet strength. Foam PVC is normally bonded or fixed mechanically instead.
Filmed, interleaved and crated. Foam board is bulky and light so it cubes out before it weighs out, and it must never be stacked under heavy rigid sheet in a mixed container.
Send your thickness, colour and quantity for a quotation
Send us these four details and we will come back with a landed cost:
- Sheet type and thickness
- Size and quantity
- Application (roof / skylight / partition...)
- Destination country or port