✓ ISO 9001 Certified Factory ✓ CE Certified / SGS Tested ✓ Ships Worldwide ✓ Free Samples Available
Get a Quote

Corrugated Polycarbonate Roofing Sheets

Corrugated polycarbonate roofing sheet is a single-skin sheet formed into a wave profile that matches a metal roof, so it can be laid into a steel roof as a daylighting run without changing the purlin layout or the fixing detail. We produce it in 0.8 mm to 1.5 mm, in the standard profiles PC760 through PC1050, clear and tinted, with UV co-extruded on the weather face.

Request a Quote Ask for Free Samples

Blue translucent corrugated polycarbonate sheet showing the wave profile

The whole value of this product is the profile match. A corrugated sheet that does not line up with the metal beside it will leak no matter how well it is fixed, and one that matches will go down with the same screws and the same laps the roofing crew already uses. This page covers the profile range, thickness choice, the single-face UV rule, spans and supply. The fixing sequence itself is in our corrugated installation guide, and the full parameter list in the 2026 specification sheet.

Corrugated Polycarbonate Sheet Specifications

Range at a glance

ProfilesPC760, PC820, PC840, PC900, PC930, PC950, PC970, PC1050
Thickness0.8 / 1.0 / 1.2 / 1.5 mm
Profile typeSingle-skin, wave profile matched to standard metal roofing
ColoursClear, opal, bronze, blue, green
Light transmissionClear 85–90 %; opal 40–50 %
UV protectionCo-extruded on the weather face only, 40–60 μm
Weightapprox. 1.0 kg/m² at 0.8 mm, 1.5 kg/m² at 1.2 mm
Service temperature−40 °C to +120 °C
Reaction to fireB-s1,d0 to EN 13501-1
StandardEN 1013 for single-skin translucent roofing
Minimum order (MOQ)1 × 20GP container — mixed profiles and colours accepted

Matching the Metal Profile Is the Whole Job

The number in the profile name is the effective cover width in millimetres — PC840 covers 840 mm once lapped. The wave underneath that number has to line up with the metal sheet it sits beside:

ProfileCover widthUsually matched with
PC760760 mmSmall-wave agricultural and light industrial roofing
PC820820 mmSmall-wave metal roofing, greenhouses, sheds
PC840840 mmCommon industrial roof profile, factory daylighting
PC900900 mmMedium-wave industrial and warehouse roofs
PC930 / PC950930 / 950 mmMedium-wave systems on wider purlin spacing
PC970970 mmLarge-wave industrial roofing
PC10501050 mmLarge-wave, large-span roofs and stadiums

Three things decide whether a match works, and all three have to be checked before the order rather than on the roof:

  • Wave pitch and depth. Two profiles can share a cover width and still differ in the wave underneath. The safest check is the metal supplier’s profile reference, not a measurement of one wave.
  • Effective cover width. The sheet is wider than the cover — the difference is the lap. Order by cover width and check the total against the run you are filling.
  • Fixing centres. The PC run is fixed at the same purlin line as the metal, at the crest of the wave, with the same fastener and washer. That is the point of a matched profile.

If the metal on site is a non-standard or unbranded profile, send us the pitch and depth and we will confirm which PC profile matches. Guessing here is the most expensive mistake on this product.

Solid Corrugated and Hollow Corrugated Are Not the Same Product

Two different sheets are sold under nearly the same name, and they are not interchangeable:

PropertySolid corrugatedHollow corrugated
SectionSingle solid wall, 0.8–1.5 mmTwin-wall with chambers, 4–10 mm
InsulationLow, U around 5.5–6.0Higher, U around 3.3–3.8
WeightAbout 1.0–1.5 kg/m²About 1.3–2.0 kg/m²
FixingStandard roofing screws through the crestNeeds closure profiles and taped ends
Used forDaylighting runs in metal roofs, canopies, claddingRoofs where insulation and condensation matter

If the brief mentions insulation, condensation or a heated space, the hollow version is the right product and it is covered in the hollow corrugated selection guide. Solid corrugated is a daylight panel, not an insulated one.

Arched steel canopy roof glazed with blue corrugated polycarbonate sheets

Thickness: 0.8, 1.0, 1.2 or 1.5 mm

  • 0.8 mm — light canopies, screens, temporary or low-access roofing. The cheapest per m² and the least tolerant of foot traffic.
  • 1.0 mm — the general-purpose roofing grade, and the most common specification for daylighting runs in industrial roofs.
  • 1.2 mm — industrial roofs where maintenance access is expected, or where hail and wind uplift loads are higher.
  • 1.5 mm — large spans, heavy snow zones, and applications where the sheet has to resist occasional loading.

UV on One Face Only — and It Has to Face Out

Unlike flat and multiwall sheet, corrugated sheet normally carries UV protection on one face only, because only one face sees the sun. That makes installation direction a real risk:

  • The UV face is marked on the protective film. Identify and mark it before the film comes off, and keep the same orientation for the whole run.
  • Installed upside down, the sheet has no UV protection on the weather side and will yellow and embrittle years early. There is no way to tell by looking after the film is gone.
  • Where a run is visible from below and the client wants a clean underside, say so at order stage — a double-sided sheet is possible but it is not the default for corrugated.

Span, Purlin Spacing and Overlap

  • Purlin spacing is set by the metal roof, and the PC run follows the same line — that is the reason to use a matched profile in the first place.
  • Side lap is one wave crest, with the PC run lapped over the metal so water runs off the metal, not under it.
  • End lap, where a run is longer than one sheet, is at least 150 mm and must fall on a purlin, lapped down the slope.
  • Snow load and wind uplift can both control the thickness; the fixings fail before the sheet does if the spacing is too wide.
  • Never walk on the sheet. Use crawling boards spanning at least three purlins if access is unavoidable.

Supply: Length, Container and Accessories

  • Length. Cut to order. Roof runs are usually measured on site first, because a sheet a bit long is scrap and a sheet a bit short is a leak.
  • Container limit. A 20 ft container takes around 5800 mm and a 40 ft around 11800 mm. Longer runs ship as two lengths with an end lap on a purlin.
  • Accessories. Matching foam closures, screws with sealing washers, ridge and verge profiles. Send the metal profile reference and we will supply the closure that fits it.
  • Packing. Filmed both sides, stacked face to face where possible, banded and crated for the container length.

Where We Are Honest About the Limits

  • It does not insulate. Single-skin corrugated is a daylight panel with a U-value near 5.8 W/m²K. If the roof needs insulation, this is the wrong product and a multiwall or hollow corrugated sheet is the answer.
  • The profile has to match, and that is on the buyer to confirm. We publish our profile range and will check a reference you send, but we cannot verify the metal on your roof from here.
  • Single-face UV means direction matters. We mark the film, but once it is stripped the responsibility for orientation is on site.
  • It is not a structural sheet. It spans between purlins at the spacing the metal dictates; it does not carry point loads, and it should not be walked on.
  • Colour is a batch property. Tinted sheets vary slightly between production runs, and a repair panel from a later batch may read as a patch.

More on Corrugated Polycarbonate

Fixing sequence, overlap details and the mistakes that cause leaks are in the installation guide; the full profile and thickness table is in the 2026 specification sheet. For everything published on this range, see the corrugated polycarbonate articles.

Corrugated Polycarbonate Roofing: Common Questions

Send us the metal supplier’s profile reference, or the wave pitch and depth in millimetres. Our profiles run PC760 to PC1050 and each is designed to match standard metal sheets; if the metal is non-standard we will confirm the nearest match from the pitch and depth rather than guess.

1.0 mm is the general-purpose roofing grade and the usual choice for daylighting runs in industrial roofs. Use 0.8 mm for light canopies and screens, 1.2 mm where maintenance access or higher wind and hail loads are expected, and 1.5 mm for large spans or heavy snow.

The UV-protected face. Corrugated sheet normally has UV on one face only, and the face is marked on the protective film. Identify it before stripping the film and keep the same orientation across the whole run, because an inverted sheet yellows and become brittle years early.

Not on its own. Single-skin corrugated has a U-value around 5.5 to 6.0 W/m2K, so it is a daylight panel rather than an insulating one. For a heated space, use hollow corrugated or multiwall sheet instead.

Side lap is one wave crest, with the polycarbonate lapped over the metal so water runs onto the metal rather than under it. End laps need at least 150 mm and must land on a purlin, lapped down the slope.

Yes, cut to order, but container length is the limit: about 5800 mm in a 20 ft container and 11800 mm in a 40 ft. Longer runs ship as two lengths with an end lap on a purlin, which is why roof measurements should be taken on site before ordering.

Send your metal profile reference and roof area for a quotation

Send us these four details and we will come back with a landed cost:

  1. Sheet type and thickness
  2. Size and quantity
  3. Application (roof / skylight / partition...)
  4. Destination country or port

Related Articles

WhatsApp · +86 187 5398 7718 info@jtpcsheet.com